top of page

How to Restart a Well Pump: Step-by-Step After an Outage

everlastingwells
Nov 14
4 min read

Updated: 33 minutes ago

After a storm, the lights come back on, the refrigerator starts to buzz and you switch on the kitchen tap. You may get no water, or a cough of air followed by a trickle. If you have a private well, this is a familiar situation and often straightforward to diagnose.

 

Your well pump is electric and it doesn't work when the power goes out. Most pumps will automatically restart when power is restored. If yours doesn't, the problem may be a tripped breaker, a switch that was left off, or a pressure switch that needs to be reset. This guide walks through the checks in order and explains when to call a pro.

 

Well Pump Won't Restart After a Power Outage

 

It helps to know what you’re dealing with before you touch anything. Most often it is due to a tripped well pump breaker, a disconnect that was not turned back on, or a pressure switch that failed to reset when power was restored.

 

A low-pressure cutoff switch is used on some well systems. It shuts off power to the pump when system pressure drops too low. If water was used during the outage, the pressure tank may have emptied and triggered the cutoff.

 

A power surge when service returns can also damage pump motors and control boxes.


 

Before You Start: Safety First

 

Wait until power is stable. Do not touch electrical equipment if the pressure tank area, basement or wellhead is flooded. Call a licensed electrician or well contractor.

 

Keep pressure-switch and electrical covers in place. Exposed terminals can carry 240 volts. Leave wiring checks, damaged electrical equipment and internal switch work to a qualified professional.

 

Step-by-Step: How to Restart Your Well Pump

 

Step 1: Turn Off Water Use in the House

 

Turn off all faucets and ensure that no one is using the dishwasher, washer or shower. Any open fixture will maintain the draining pressure and will make it more difficult for the pump to regain pressure.

 

Step 2: Check the Breaker Panel

 

Look for the breaker labeled “well,” “pump” or “WP.” If the panel and floor are dry and there are no signs of damage, reset a tripped breaker once by moving it fully to OFF, then to ON. If it trips again, leave it off and call a qualified professional.

 

If the panel is not labeled, have the pump circuit identified and labeled before the next outage.

 

Step 3: Check the Disconnect Switch

 

There is usually a switch or fused disconnect near the pressure tank. Make sure the accessible switch is on. If the pump has a separate control box with an external reset button, follow the manufacturer's instructions for that model.

 

Step 4: Read the Pressure Gauge

 

Check the pressure gauge on or near the pressure tank. A reading near zero while the pump is quiet can indicate a low-pressure cutoff, a lack of power or another equipment issue.

 

Step 5: Reset the Pressure Switch Lever

 

Some pressure switches have an external low-pressure reset lever. If your model has one and the manufacturer allows homeowners to use it, follow its manual with the switch cover in place. Lever positions and pressure thresholds vary. Stop if the pump fails to build pressure or the cutoff trips again. A switch without an external reset should be inspected by a professional if the pump still won't start.

 

Step 6: Bleed Air From the Lines

 

Once the tank is full, turn on a cold water faucet, preferably a bathtub spigot that has no aerator. Initially, there will be sputtering and air. Run until a clear stream is obtained. If flooding may have contaminated the well, follow the water-quality guidance below before using the water.

 

Step 7: Prime the Pump (Shallow-Well Jet Pumps Only)

 

Submersible pumps are located in the well and do not require priming. Above-ground jet pumps may lose their prime. Follow the manufacturer's instructions for shutting off power, relieving system pressure and priming your model, or call a well contractor. Do not run a jet pump dry, as this can damage the impeller and seals.


 

When to Stop and Call a Professional

 

Contact a licensed well contractor if the breaker trips again, the pump runs without building pressure, you smell burning insulation, or water stays sandy, cloudy or full of air. Avoid repeated restarts, which can worsen pump damage. A well inspection can help isolate the cause.

 

Don't Forget Your Water Quality!

 

If the outage was accompanied by flooding, use bottled water for drinking and cooking. Follow Connecticut DPH guidance and have the well evaluated. After disinfection, arrange well water testing through a state-certified laboratory before drinking the water again.

 

If you have a water softener or filter, check its settings when power returns. Follow the manufacturer's instructions if a manual regeneration or backwash is needed.

 

What to Do in the Event of the Next Outage

 

Label your breaker and note where the disconnect switch is. Stop using water as soon as the power goes out to preserve pressure in the tank.

 

Ask a licensed electrician about surge protection and backup power. A generator must handle the pump motor's startup load and be connected through appropriately installed transfer equipment. Keep emergency drinking water on hand.

 

Frequently Asked Questions

 

Does the well pump automatically restart when the power returns?

 

Usually, yes. Some systems with a low-pressure cutoff need to be reset manually if the tank emptied during the outage.

 

How long do I need to press the switch lever?

 

Follow the instructions for the exact switch model. If the gauge does not rise or the reset will not hold, stop and call a well contractor.

 

Why is my pump running and I don't have any water pressure?

 

A jet pump may have lost its prime, the water level may be below the pump intake, or there may be a leak or broken pipe. Turn the pump off if it is running without building pressure and call a well professional.

 

Is it OK to use a portable generator to power my well pump?

 

Yes, if it can handle the motor's startup load and a licensed electrician has installed appropriate transfer equipment. Never backfeed power through a dryer outlet.

 

After a power outage, is it safe to drink well water?

 

A routine outage without flooding or damage does not by itself establish contamination. If floodwater reached the wellhead, or the well may be contaminated, use bottled water until the well has been disinfected and a certified laboratory confirms it is safe.

 
 
 

Comments